Industrial Strength Isolator Switches - Ensure Complete Disconnection

Heavy duty electrical isolator switches provide indispensable capabilities to safely disconnect equipment from energized circuits across industrial and utility sites. When properly installed and maintained, the robust electromechanical isolators continue providing reliable on/off control over millions of cycles lasting decades.

GRL offers IEC-compliant isolators with UL/CSA certification to meet the most stringent application needs for capacitive loads, availability, and personnel protection. For additional guidance selecting suitable isolator switches rated for your system voltage and current, contact our team of specialists to keep your vital electrical systems isolated yet controlled. Contact us if you need.

Play Video about GRL products

Table of Contents

Introduction

Isolator switches, also known as safety disconnect switches, provide manual isolation of electrical circuits to cut off power to equipment for servicing or during emergencies. Heavy duty isolator switches are essential across industrial environments, utilities, and large commercial facilities to safely disconnect equipment while energized circuits remain live nearby. This guide covers isolation switch types, ratings, installation, and key benefits that make them indispensable protection and safety components.

Types of Isolator Switches

Common industrial isolator switch varieties include:

Disconnect Switches – Enclosed switches used to disconnect power to individual circuits or equipment sections. Provide visible blade separation and padlocking provisions.

  • Rotary handles allow quick isolation by separating stationary contacts.
  • Used extensively for distribution equipment, panelboards, motors, and machinery.
  • Ampacities from 30A to 6000A. 600VAC voltage ratings commonly used.

Knife Switches – Allow quick manual isolation of high current load break applications. Used extensively in mining switchgear and medium voltage settings. Exposed blades require caution.

  • Open knife blades physically separate to isolate and stop current flow.
  • Used in switchgear controlling generators, motors, transformers, and distribution lines.
  • Ampacities up to 5000A. Medium voltage ratings from 5kV to 38kV.

Fuse Combination Units – Combine isolation switches with replaceable fuses for overcurrent protection and coil control capabilities. Used for large motors and transformers.

  • Allow isolating equipment and safely changing fuses.
  • Fuse ratings from 15A up to 6000A at 600VAC.
  • Visible blown fuse indication flags overload issues.

High Voltage Isolators – Gang operated switches designed for medium voltage equipment isolation. Utilize multiple breaks and SF6 gas insulation suited to 15kV+ isolation duty.

  • Insulated stacked breaks extinguish arcs during opening.
  • Primarily used in utility outdoor substations and switchyards above 38kV.

DC Isolators – Specialized disconnect switches designed for 400V-1000V DC isolation duty in battery banks, solar farms, traction systems and data centers.

  • Address DC arc hazards and switching challenges.
  • Required for isolation and maintenance of DC equipment.

Choosing the appropriate isolator switch type provides safe, reliable isolation across voltage levels from 120VAC to 38kV.

Important Specifications

Key isolator switch characteristics include:

Voltage Rating – Must match system voltage with sufficient safety margin. Medium voltage switches use insulation like SF6 gas or vacuum.

  • 1000V, 2000V, 5000V and higher ratings available.
  • Insulation materials determine max voltage withstand.

Current Rating – Ampacity must meet or exceed the protected circuit current demands and fault capacity.

  • From 30A to 6000A ratings or more to suit specific loads.
  • Thermal and short circuit withstand capacity.

Poles – Single or multi-pole configurations suitable for the number of isolated phases and conductors. 3-pole commonly used.

  • Up to 6-pole isolators available for complex circuits.

Enclosures – Appropriate NEMA ratings for indoor/outdoor use. Stainless steel for corrosive locations.

  • NEMA 1, 3R, 12 ratings for indoor, outdoor needs.

Accessories – Fuses, auxiliary contacts, heater elements, interlocks customize switches.

  • Shunt trips, bell alarms, fuses, auxiliary switches add capabilities.

Carefully selecting isolators matched for the application voltage, current, speeds, and accessory needs ensures suitability for the specific isolation application.

Benefits of Isolator Switches

Isolators provide key advantages:

Total Visible Isolation – Double or multi-break switch designs provide complete physical air gaps across all poles for assured separation.

  • Allows seeing switch contact separation for safety.

Allows Safe Maintenance – De-energization with locked-open switches lets technicians service equipment without dangerous live current exposure.

  • Essential for electrical safety and OSHA compliance.

High Reliability – Proven robust electromechanical operation for infrequent but critical isolation duty lasts decades.

  • Components engineered for millions of lifetime operations.

Reduced Arc Flash Hazards – Fast, positive action quenches arcs during switching. Lower risk to personnel than breakers.

  • Safer isolation method compared to just relying on breakers.

Flexible Options – Wide selection of voltages, configurations, enclosures, and accessories fit diverse needs.

  • Tailor isolators to specific requirements.

Safely de-energizing equipment circuits via isolator switches protects both personnel servicing equipment and the connected electrical system.

Standards and Testing

Quality isolators comply with:

IEC 60947 – International standard defining isolator switch testing methods and specifications like dielectric strength, insulation resistance, short circuit capacity.

  • Basis for defining isolator construction and testing.

UL 98 and UL 489 -North American standards dicturing required safety mechanisms and test procedures. Certification by Underwriters Laboratories.

  • Third-party certification of safety and performance.

Temperature Rise Tests – Verifies current carrying components do not exceed temperature limits during full load conditions per established standards.

  • Confirms thermal endurance for continued operation up to rated amperage.

Making/Breaking Tests – Confirms isolator ability to reliably open and close circuits under specified test conditions without failure.

  • Ensures switch lasts across mechanical lifetime specifications.

Certified commercial and industrial grade isolators withstand the rigors of harsh environments and fault currents over long service lives.

Selection Guidelines

Properly selecting isolators involves verifying:

Voltage Rating – Isolator switch voltage class must equal or exceed the system voltage.

  • Select 125V, 250V, 600V etc. switches to suit circuit voltage.

Current Rating – Isolator ampacity must meet or surpass maximum anticipated circuit current.

  • Choose 30A, 60A, 100A up to thousands of amps as required.

Number of Poles – Single or multiple poles depending on number of conductors being isolated.

  • One, two, three, or four pole isolators are commonly available.

Enclosure Type – Environment dictates need for NEMA 1, 3R, 4X, 12 enclosures.

  • Indoor, outdoor, wet location, and chemical resistant options.

Speed – Standard speed suffices for most applications. Choose high speed versions only when necessary.

  • Faster operation for interrupting capacitive or inductive loads.

Matching isolator specifications to circuit and environmental demands ensures optimal performance, protection, and safety.

Installation and Maintenance

Properly installing and servicing isolators ensures optimal function:

Secure Mounting – Mount enclosures rigidly to walls or frames designed to support weight using manufacturer instructions.

Straight Short Conductors – Keep circuit length between the isolator and connected equipment as short and straight as possible. Minimize complex bends.

Adequate Workspace – Ensure sufficient space around isolators for full range of motion, doors to fully open, and NEC working clearance zones.

Convenient Location – Install at working height near associated equipment for easy access during servicing.

Routine Lubrication – Apply manufacturer recommended lubricants to hinge pivots, bearings and sliding joint areas before energization to prevent binding. Reapply periodically.

Test Before Re-Energizing – Manually operate isolator multiple times and visually inspect to confirm proper isolation before returning to service.

Following defined installation and maintenance procedures improves isolator performance, lifespan, and availability.

Safety Recommendations

Working with industrial isolators demands strict adherence to safety:

Personal Protective Equipment – Always wear properly rated rubber gloves, sleeves, matting and full eye protection when operating medium voltage isolators.

Lockout/Tagout – Use lockout devices and tags as required during maintenance to prevent accidental reactivation of isolated circuits.

Signage – Warning signs indicating high voltage and instructions help prevent improper operation. Install safety barriers as needed.

Voltage Verification – Always use a properly rated voltage detector to reconfirm deenergized status on isolated circuits before servicing. Assume lines are live until proven dead.

Current Phasing – Check phasing before reconnecting isolated equipment or circuits to avoid out-of-phase closing.

Exercising extreme caution is mandatory when working on or near hazardous high voltage switchgear and isolators to prevent tragic electrical accidents. Safety training, procedures and equipment must be diligent.

GRL Isolator Switches

GRL manufactures premium quality, safety certified isolator switches trusted by leading utilities, solar farms, manufacturers, metals and mining firms.

Industrial Grade Construction – Heavy duty interrupter mechanisms, bearing pivots and enclosure withstand harsh conditions and fault currents.

  • Designed for millions of lifetime operations with consistent performance.

Stringent Quality Control – 100% production testing ensures rated performance for voltage, current, fault capacity and mechanical endurance.

  • Every isolator rigorously tested before shipment.

Robust and Reliable – Components engineered for long service life spanning millions of maintenance cycles.

  • Built to operate consistently over decades.

Custom Designs Available – Application engineers tailor isolators to your specific voltage, configurations, options.

  • Unique requirements can be accommodated.

Global Delivery – Large product inventory ships promptly anywhere worldwide.

  • Fast delivery from warehouses in Asia, Europe and North America.

Contact GRL engineers today to review your isolation switch requirements. Our specialists can recommend cost-effective solutions to maximize safety.

GRL - Isolator Switch

Frequently Asked Questions

What is an isolator switch?

An isolator switch, also called a safety disconnect switch, is a manually operated electrical switch designed to completely isolate and de-energize a circuit to shut off power to downstream equipment. Key characteristics include:

  • Allowing physical separation of contacts to stop current flow for disconnection of power.

  • Providing a point of isolation so a circuit can be de-energized for maintenance or modifications.

  • Serving as a means of locking-out hazardous energy sources for worker protection during servicing.

  • Ability to totally isolate an electrical branch without affecting adjacent energized circuits.

  • Robust mechanical design with high fault standoff capacity spanning millions of operations.

  • Options like fuses, interlocks, and remote operators add functionality.

By providing complete isolation and a physical break in live circuits, isolator switches establish a key safeguard enabling electrical safety compliance in industrial facilities and distribution systems.

 

Why are isolator switches used?

Isolator switches serve several vital functions:

  • Allow technicians to manually and visually confirm electrical circuits have been safely de-energized for maintenance activities like equipment repair. This saves lives and prevents arc flashes.

  • Provide a means of locking out hazardous energy sources using padlocks by isolating equipment from live power. Critical for electrical safety procedures and compliance with regulations.

  • Act as an emergency shutdown switch to quickly isolate circuits from power in a crisis until main breakers can be accessed.

  • Enable verification of safe isolation by voltage testing before maintenance work begins.

  • Allow individual branch circuits to be disconnected without disruption to adjacent energized circuits and critical processes.

  • Can incorporate accessories like fuses for overcurrent protection, shunt trip coils, and auxiliary contacts.

Safely controlling electrical hazards relies on strategically placed isolator switches to manually stop current flow to Equipment.

 

What are the different types of isolator switches?

Common isolator switch varieties include:

  • Disconnect switches – Enclosed switches used extensively to isolate distribution and control equipment up to 600V. Rotary handles provide isolation.

  • Knife switches – Provide quick visible isolation in medium voltage switchgear. Used for generators, motors, transformers. Exposed blades.

  • Fuse combination units – Enclosed switches that incorporate fuses for overcurrent protection of downstream circuits. Allow fuse access.

  • High voltage isolators – Gang operated switches utilizing insulated stacks for voltages from 15kV to 38kV. Used at utility substations.

  • DC isolators – Specialized disconnect switches designed for 400V-1500V DC applications like solar farms and battery banks.

  • Hookstick operated isolators – Allow hot stick operation by utility line workers to isolate overhead distribution lines.

Various isolator designs match different voltage and current interruption needs across electrical systems.

 

What are the applications of isolator switches?

Isolators have many applications across industrial facilities and utilities:

  • Isolating large motors, conveyors, pumps, and machinery for repair.

  • De-energizing sections of manufacturing equipment to allow safe access.

  • Locking out drawout circuit breakers for maintenance.

  • Cutting power to industrial furnaces, boilers, compressors during servicing.

  • Isolating generators and switchgear before inspection and maintenance.

  • Disconnecting utility transformers and capacitors for field work.

  • Providing emergency shutdown of equipment.

  • Lockout/tagout procedures when working on hazardous energy sources.

  • Allowing voltage measurement for absence before maintenance.

Any application requiring reliable and verifiable electrical isolation for safety benefits from proper isolator switch placement and usage.

 

What voltage ratings are isolator switches available for?

Isolator switches are produced with voltage ratings spanning from 125V single phase up to 38kV on high voltage systems:

  • 120V, 208V, 240V – Single phase isolators for lighting and building distribution applications.

  • 480V, 600V – Three phase switches rated for typical plant distribution voltage levels.

  • 2.3kV, 4.16kV – Medium voltage isolation for generators, motors, switchgear, and transformers.

  • 15kV, 27kV – Higher voltage models used extensively in utility substation applications.

  • 1000V DC – For battery banks, solar farms, traction power, and DC applications.

Proper insulation, contact separation, and pole configurations allow isolator designs spanning low voltage to high voltage systems.

 

What are the important specifications of isolator switches?

Key electrical and mechanical specifications include:

  • Voltage rating – Maximum voltage that can be safely isolated. 600V, 5kV etc.

  • Current rating – Continuous and fault current the switch can safely interrupt. 100A, 800A etc.

  • Short circuit rating – Measures fault standoff capacity. 10kA, 65kA etc.

  • Number of poles – Poles match number of isolated conductors. Up to 6 poles.

  • Switch type and speed – General purpose, double break, quick-make, quick-break etc.

  • Contact termination type – Lugs, buses, taps.

  • Mechanical lifetime – Switch cycles before contact replacement needed. 1 million+

  • Enclosure rating – NEMA 1, 3R, 4X etc. environmental protection.

  • Accessories – Fuses, interlocks, aux contacts add functionality.

Carefully comparing specifications ensures the isolator switch rating suits the electrical system parameters and site conditions.

 

What are the advantages of isolator switches?

Benefits provided by properly utilized isolator switches include:

  • Visible isolation – Double break designs allow physical confirmation of separation for safety.

  • Safer circuit isolation – Positively interrupts current flow without questionable contact gaps. More reliable than just breakers.

  • Allows equipment maintenance – De-energized state verified by absence of voltage.

  • Reduced arc flash hazards – Fast interrupting designs quench arcs quickly. Lower risk than breakers.

  • Enables lockout/tagout – Padlocks physically prevent reactivation for worker protection.

  • Long service lifespan – Robust switches rated for millions of operations over decades.

  • Added capabilities – Accessories like fuses, aux contacts, trip coils provide options.

Safety and maintaining uptime across electrical systems relies on strategic application of isolation switches for outfitting equipment circuits.

 

How does an isolator differ from a circuit breaker?

While both open circuits, key differences between isolators and circuit breakers include:

  • Isolators are manually operated electromechanical switches that provide foolproof isolation. Breakers trip automatically based on current sensing.

  • Isolators provide a visible, verifiable physical break or air gap when opened. Breakers use uncertain contact separation invisible to users.

  • Isolators can incorporate padlock provisions for lockout/tagout safety procedures. Breakers cannot be physically locked to prevent manual closing.

  • Isolators are designed for repeated on/off manual operation under no load conditions. Breakers open automatically under fault conditions.

  • Isolators require external overcurrent protection like fuses. Breakers incorporate overcurrent tripping internally.

  • Isolators offer lower arc flash hazard during switching. Breakers can produce high-energy arcs when tripping.

The definitive isolation and lockout abilities make isolators indispensable electrical safety devices complementing standard circuit breakers.

Contact Us Now

If you have any questions or would like to receive a free sample, please contact us and the GRL team of professionals will be happy to assist you.

GRL‘s Honor Products

60mm busbar system

Busbar System

60mm/100mm/185mm/terminal distribution Busbar System

GRL Fuse type disconnect switch

Disconnect switch

Fuse type disconnect switch

GRL-Knife switch

Knife switch

Different kinds of Knife switch

GRL Fuses and Fuseholders

Fuse & Fuse holders

Fuse & Fuse holders

You'll receive a response ASAP!