Busbar short circuit faults present a major threat to reliability and safety of electrical systems. A range of factors can precipitate dangerous short circuit conditions on the busbar like insulation failures, physical damage, overvoltages and poor connections. Swift detection and isolation using properly rated current limiting fuses, fast breakers and busbar differential protection is vital to limit equipment damage, fire hazards and injury risks. Maintenance checks, protective relaying and arc resistant designs help restrict the damage when faults do occur.
Contact for more infomation. GRL‘s team of engineers will provide you with professional services and satisfactory solutions.
A busbar is a metallic strip or bar used to connect high current carrying equipment like switchgear, transformers and generators in electrical power systems. Busbars are found in distribution boards, switchboards, motor control centers and power stations.
Busbars allow easy tapping of connections to different circuits. They also minimize voltage drop due to lower resistance compared to cables. Common busbar materials are aluminum or copper as they provide high electrical conductivity.
Being a central power distribution component, busbar failures can have serious consequences. One such issue is a busbar short circuit fault. This article looks at the causes, effects, detection and protection methods for busbar short circuit faults.
Some common causes of busbar short circuit faults are:
Busbars in medium and high voltage systems require insulation sleeves or barriers between phases and between phases and ground. Degradation of insulation due to aging, overheating or moisture absorption can lead to shorting faults.
Accidental contact between busbars and external tools, dropped objects or animals can provide shorting paths resulting in high currents.
Voltage spikes induced by lightning or switching surges can puncture busbar insulation leading to flashover failures.
Variation in system frequency applies mechanical stress on busbars and joints. This can loosen connections and reduce insulation strength over time.
Loose busbar joints due to improper torque or corrosion results in localized heating which further deteriorates the contacts. This can eventually melt the connections and trigger a short circuit.
Mechanical damage due to accidents, mishandling during maintenance or insulation cracking due to vibrations can expose the bare busbars. This allows flashovers between phases or to earth.
Busbar short circuit faults result in:
The low impedance short circuit path allows huge currents to flow which rapidly heats up and vaporizes the conductors. This creates a hot, high energy electrical arc with intense heat and pressure blast effects.
The massive energy released can deform and puncture bus enclosure walls. Connected substation equipment like transformers may also be damaged either by direct arcing or by the propagating high currents.
The short circuit fault rapidly drains power from generators and upstream lines. This sags the voltage causing tripping of upstream breakers and a shutdown of the electrical system leading to an outage.
The high temperatures can melt insulation and ignite flammable materials nearby. The arc energy can also cause fires by igniting dust or gases in the area.
The explosive pressures and molten metal splatter from the electrical arcing poses a grave danger to operating personnel. Injuries can range from burns to permanent disability or even death.
To prevent damage, busbar short circuits need to be detected rapidly. This can be done by:
Regular inspection of busbars and connections to spot cracks, overheating signs or loose bolts. Infrared thermography can help detect hotspots.
Installing temperature sensors at critical busbar joints to trigger alarm on over-temperature rises from joint deterioration or loosening.
Busbar differential or distance protection relays to swiftly detect fault conditions by measuring abnormal current or impedance changes.
To limit the impact of a busbar short circuit, fast acting protective systems are essential. Common busbar protection methods include:
Fuses with current limiting effect allow high speed clearance by introducing high resistance once current exceeds preset threshold. This suppresses peak short circuit current.
Molded case and gas insulated breakers designed for high speed tripping and interruption within 2-3 cycles after detecting overcurrent. This limits energy released.
Relays compare busbar current entering and leaving using CTs. If difference exceeds threshold, relay issues trip signal to isolate the faulted section.
Continuously monitors insulation resistance to ground. Early warning of any insulation degradation is available to prevent breakdown.
Consider these factors when choosing appropriate busbar short circuit protection:
The maximum prospective short circuit current must be known. Protection device should be rated for safe interruption of this current.
Faster protection operation minimizes risks and damage. Current limiting fuses operate within half cycle while breakers isolate in 2-3 cycles.
Must properly coordinate (selectivity) with downstream fuses and circuit breakers to avoid unnecessary tripping of healthy circuits.
Fuses limit peak current while providing backup protection. Breaker provides speed. Combined, they offer better busbar short circuit protection.
Some ways to limit the severity of busbar short circuit damage include:
Regular thermal scans, insulation testing and visual inspection during maintenance outages to detect any deterioration well in time.
Use protection relays, temperature sensors and monitoring equipment to swiftly detect any abnormal busbar conditions.
Employ fast-acting, properly rated current limiting fuses and circuit breakers to quickly isolate the faulted section while allowing unaffected sections to remain energized.
Arc resistant switchgear construction like arc diverters and pressure vents minimize arcing damage and control blast pressures.
Busbar short circuit is an abnormal low impedance current path that occurs phase-to-phase or phase-to-ground between the bus conductors due to factors like insulation failure, external objects, overvoltages etc. It results in a huge flow of fault current.
It occurs when electrical clearance between busbar phases or between phases and ground is bridged by a low impedance material like a tool drop or carbonized insulation. This provides an easy path for flashover and the busbar wrongly feeds very high short circuit current into the fault.
Common causes are insulation deterioration, accidental contact by objects or animals, loose connections overheating and breaking down insulation, overvoltages puncturing insulation, and physical busbar damage due to mishandling or corrosion.
Effects include very high short circuit currents resulting in severe arcing and rise in temperatures. This can damage connected equipment, pose fire and explosive hazards, and cause power outage. The arc energy can also injure or kill operating personnel.
Short circuit current in directly connected busbar systems can reach over 200 kA within few cycles. But limited only by source impedances, it can theoretically reach over 1 MA in the first peak. This immense energy can cause violent damage.
Busbar short circuits can be detected by temperature sensors, visual inspection of connections, insulation monitoring devices, and protection relays that measure abnormal current or impedance changes from the busbar to detect any faults.
Protection involves current limiting fuses and fast circuit breakers to limit and interrupt fault currents. Busbar differential protection also isolates only the faulted sections while keeping others energized. Preventive maintenance and arc resistant designs also help minimize damage.
It is a relay that monitors for short circuit conditions on the busbar using CTs and Rogowski coils connected to each branch and bus section. Sudden differential current or impedance change triggers fast tripping of breakers isolating the fault.
They introduce a high resistance once current exceeds a preset level to limit and interrupt the current. This reduces peak short circuit current and arc energy. They operate within 1/2 cycle and help protect busbars.
Select device like fuses and breakers with short circuit interrupting rating higher than maximum prospective short circuit current. Also ensure fast operation in < 5 cycles and proper coordination with downstream devices.