Reliable 3 Phase Disconnect Switches for Power Distribution

Whether providing integrated protection or reliable isolation, 3 phase disconnect switches enable safer isolation and maintenance for motors, HVAC, and electrical systems. With diverse mounting, enclosure, and feature options, choosing the ideal 3 phase disconnect depends on your unique technical specifications and requirements.

By evaluating key factors like quality, lead times, and customization, you can select optimized 3 phase disconnect switches from trusted manufacturers like GRL. Proper installation, operation, and maintenance ensures your 3 phase switches consistently provide isolation and protection over their service life.

Contact the experts at GRL today to discuss how we can supply high-performance 3 phase disconnect switches for your specific application, backed by decades of engineering expertise.

Play Video about GRL products

Introduction

A 3 phase disconnect switch is an essential device for safely isolating and shutting off electrical equipment for service and maintenance. Selecting the right 3 phase disconnect switch ensures reliable power distribution and protection across industrial facilities, commercial buildings and critical infrastructure.

This guide provides a comprehensive look at 3 phase disconnect switches, types, installation considerations, applications, and factors for choosing the ideal switch. With robust ratings up to 6000A, GRL 3 phase disconnect switches are engineered to handle demanding electrical loads across sectors.

 

Types of 3 Phase Disconnect Switches

3 phase disconnect switches come in different configurations:

Fused Disconnect Switches

Fused disconnect switches contain removable fuses providing overcurrent protection. They isolate the circuit when amps exceed the fuse rating.

Features:

  • Overcurrent and short circuit protection
  • Amp ratings from 30A to 6000A
  • 2 and 3 pole options
  • Visible contact position
  • 10kA+ SCCR ratings

Benefits:

  • Protection and disconnection in one device
  • Easily replace fuses to reset
  • Rated up to 35kV voltage systems
  • Withstand high available fault currents
  • Heavy duty industrial construction

Fused switches safely disconnect equipment in overload events.

Non-Fused Disconnect Switches

Non-fused switches provide isolation without overcurrent protection. Types include:

Isolator Switches

  • Quick break opening mechanisms
  • Robust handles with lockout/tagout
  • Heavy duty enclosed cases

Knife Switches

  • Exposed terminals for convenient access
  • Basic on/off manual operation
  • Cost effective isolation

Motorized Switches

  • Electric or hydraulic actuators
  • Remotely operable
  • Integrated monitoring capabilities

Non-fused switches enable flexible control for straightforward isolation needs.

Enclosed and Open Types

3 phase disconnect switches come in enclosed and open variations:

Enclosed Switches

  • Sheet metal or plastic cases
  • Safety shrouds over current carrying parts
  • More knockout locations for conduit
  • Rainproof and watertight options

Open Switches

  • Exposed components and terminals
  • More economical than enclosed
  • Smaller footprint
  • Mount to backpanels or frames

Enclosed designs provide protection for public access areas. Open types optimize space requirements.

 

Installation Considerations for 3 Phase Disconnects

Properly installing and wiring a 3 phase disconnect ensures safety and performance:

Mounting Location

  • Install near equipment being disconnected for ease of access.
  • Allow adequate working space to open door.
  • Use suitable NEMA rated enclosures.

Electrical Connections

  • Follow all NEC and local codes for size and installation.
  • Use copper wires, sized for ampacity.
  • Tighten lugs to specified torque values.

Safety Checks

  • Verify switch amp rating exceeds connected equipment.
  • Apply arc flash and shock hazard labels.
  • Test operation and inspect alignments.
  • Check remote monitoring functionality.

Careful installation, wiring, and inspection prevents issues and ensures optimal operation.

 

Applications of 3 Phase Disconnect Switches

3 phase disconnect switches provide versatile isolation:

Industrial Manufacturing

  • Isolate motors, pumps, compressors, and conveyors
  • Disconnect machine tools for maintenance
  • Transfer switches for backup power

Commercial Buildings

  • Safely disconnect HVAC and rooftop units
  • Isolate lighting panelboards
  • Meet code for kitchen equipment

Solar Farms

  • Disconnect strings of solar panels
  • Combiner boxes with fuses for overcurrent protection

Data Centers

  • Orderly shutdown of server racks
  • HVAC equipment isolation
  • Transfer switches for UPS systems

Electrical Utilities

  • Isolate transformers, switchgear and substations
  • Remote operation capabilities

3 phase disconnect switches enable versatile isolation up to 6000A across sectors.

 

Buying Factors for 3 Phase Disconnects

Key considerations when selecting 3 phase disconnect switches:

Price

  • Balance upfront cost with reliability and lifespan.
  • Opt for trusted brands that offer value.

Quality and Ratings

  • Industrial grade components last longer.
  • High short circuit current ratings ensure safety.
  • Look for rigorous testing procedures.

Brand Reputation

  • Experienced companies offer proven designs.
  • Strong customer support eases purchasing.

Lead Times

  • Quick delivery enables faster project completion.
  • Some brands ship orders within 24 hours.

Customization

  • Tailor disconnects to your exact specifications.
  • Select required poles, NEMA ratings, and accessories.

Evaluating switches across these metrics helps identify the right options.

 

Why Choose GRL for 3 Phase Disconnects

With over 25 years as a leading disconnect switch manufacturer, GRL provides high-quality 3 phase switches tailored to your needs:

Field Proven Reliability

  • Components tested to 10,000+ mechanical cycles
  • Strict quality control procedures
  • Rigorously certified to global standards

Precise Customization

  • Exact electrical specs you require
  • Wide selection of enclosures, poles and accessories
  • Specialized options like remote monitoring

Global Expertise

  • Complete in-house engineering through production
  • Ships switches for projects worldwide
  • Local sales and technical support

Fast Delivery

  • Ships most orders within 3-5 days
  • Get products when you need them

Tested Quality

  • Free samples to evaluate products
  • Thoroughly test construction and performance
  • Verify suitability before purchasing

GRL combines quality, customization, and quick delivery to provide the right 3 phase disconnect switch.

GRL-3 phase disconnect switches

Frequently Asked Questions

What are 3 phase disconnect switches used for?

Three-phase disconnect switches are electrical devices used in three-phase electrical systems to provide a means for safely disconnecting power from circuits, equipment, or machinery. They play a crucial role in various applications, ensuring safety during maintenance, servicing, emergency shutdowns, and other scenarios. Here are some common uses of three-phase disconnect switches:

  1. Motor Control: Disconnect switches are often used in motor control circuits to isolate three-phase motors from the power source. This is essential for maintenance, servicing, and emergency shutdowns, especially in industrial settings.

  2. Control Panels: Three-phase disconnect switches can serve as the main disconnect within control panels and distribution boards. They provide a way to disconnect power to the entire panel for maintenance or safety purposes.

  3. Power Distribution: In electrical distribution systems, disconnect switches are used to isolate specific circuits or sections of the distribution network. This can facilitate maintenance and repairs without affecting the entire system.

  4. Lighting Control: In commercial and industrial buildings, disconnect switches are used to control lighting circuits, allowing for safe maintenance or emergency shutdowns.

  5. Heating and Cooling Systems: Disconnect switches may be employed in heating, ventilation, and air conditioning (HVAC) systems to isolate power for maintenance and servicing.

  6. Industrial Machinery: Three-phase disconnect switches are used for isolating power to various industrial machinery, including pumps, compressors, conveyors, manufacturing equipment, and more.

  7. Safety and Emergency Shutdowns: Disconnect switches play a critical role in ensuring electrical safety. They are used to quickly and easily de-energize circuits in the event of an emergency, fault detection, or when work needs to be performed on electrical systems.

  8. Backup Power Systems: In backup power systems, disconnect switches are used to transfer power between the primary power source and backup generators or uninterruptible power supplies (UPS).

  9. Alternative Energy Systems: Disconnect switches are often integrated into solar and wind power systems to disconnect power generated by renewable energy sources from the electrical grid for maintenance and safety.

  10. Agricultural Applications: Disconnect switches can be found in agricultural machinery, irrigation systems, and other agricultural equipment to provide a means of isolating power.

The specific application of three-phase disconnect switches may vary based on the requirements of the electrical system and the equipment being controlled. It’s crucial to follow local electrical codes and safety regulations when using these switches to ensure safe and compliant operation.

 

What are the different types of 3 phase disconnect switches?

Three-phase disconnect switches come in various types and configurations to meet the specific needs of different applications. The choice of the disconnect switch type depends on factors such as the intended use, environmental conditions, and safety requirements. Here are the different types of three-phase disconnect switches:

  1. Non-Fused Disconnect Switches: Non-fused disconnect switches provide a means to disconnect power without built-in overcurrent protection. They are typically used for isolating circuits or equipment for maintenance and safety purposes. Non-fused disconnect switches are simple in design and do not include fuses for overcurrent protection.

  2. Fused Disconnect Switches: Fused disconnect switches incorporate fuses as part of the design to provide overcurrent protection for circuits or equipment. Fused disconnect switches are used in applications where protecting against overloads and short circuits is required. They offer selective protection, meaning that only the faulted circuit is disconnected, while other circuits remain operational.

  3. Enclosed Disconnect Switches: Enclosed disconnect switches are mounted in protective enclosures that shield the switch from environmental factors, such as dust, moisture, and corrosive substances. These switches are suitable for outdoor use, harsh industrial environments, or locations with specific environmental challenges.

  4. Open Disconnect Switches: Open disconnect switches do not have an enclosure and are designed for indoor use in controlled environments. They are commonly used in commercial and industrial settings where the environment is clean and dry.

  5. Knife Blade Disconnect Switches: Knife blade disconnect switches feature a knife-like blade that moves to open or close the circuit. These switches provide a visible break and are often used in industrial applications to ensure quick and reliable power disconnection.

  6. Rotary Disconnect Switches: Rotary disconnect switches have a rotary handle that can be turned to open or close the circuit. They are user-friendly and often used in motor control applications and control panels.

  7. Pistol Grip Disconnect Switches: Pistol grip disconnect switches feature a pistol-shaped handle for easy operation and are commonly used in industrial applications where a secure grip is necessary for safety and operation.

  8. Cam Switches: Cam switches use a rotating cam mechanism to make or break electrical connections. They are versatile and can be used in a variety of applications, including industrial control and power distribution.

  9. Motor Disconnect Switches: Motor disconnect switches are specifically designed for controlling and disconnecting three-phase motors. They provide a convenient means for isolating motor power during maintenance or emergencies.

  10. Safety Disconnect Switches: Safety disconnect switches are equipped with additional safety features, such as padlockable handles, shrouded terminals, and the ability to be locked out/tagged out for maintenance and safety purposes.

  11. Combination Starters: Some combination motor starters incorporate a disconnect switch as part of the assembly. These devices combine motor control and overcurrent protection in one unit.

The choice of the appropriate type of three-phase disconnect switch depends on the specific application, safety requirements, environmental conditions, and the need for overcurrent protection. Always ensure that the selected disconnect switch complies with local electrical codes and standards and is suitable for the intended use.

 

How does a 3 phase disconnect switch work?

A three-phase disconnect switch, also known as a three-pole disconnect switch, is a manually operated electrical device designed to disconnect power from a three-phase electrical circuit or load. It works by physically interrupting the flow of electrical current between the power source and the load. Here’s how a three-phase disconnect switch typically works:

  1. Manual Operation: Three-phase disconnect switches are typically operated manually. They have a handle or operating mechanism that can be turned or moved to either the “ON” or “OFF” position. When the handle is in the “ON” position, the switch allows electrical current to flow through it. When in the “OFF” position, it interrupts the electrical connection.

  2. Contact Mechanism: Inside the disconnect switch, there are electrical contacts or terminals. In the “ON” position, these contacts are engaged, allowing the electrical current to pass through the switch. In the “OFF” position, the contacts are disengaged, creating an open circuit and preventing the flow of electricity.

  3. Visible Break: Many disconnect switches are designed to provide a visible break. This means that when the switch is operated to the “OFF” position, the contacts are separated in a way that is easily visible to the operator. This visible break helps ensure that the circuit is safely disconnected.

  4. Arc Suppression: Disconnect switches are designed to minimize the creation of electrical arcs when the contacts are separated. Arc suppression mechanisms, such as arc chutes or arc extinguishing chambers, help extinguish any arcs that may form during disconnection, enhancing safety and preventing damage to the contacts.

  5. Lockout/Tagout: Many disconnect switches are equipped with provisions for lockout/tagout. This allows authorized personnel to secure the switch in the “OFF” position with a lock and tag, providing an extra layer of safety during maintenance or servicing.

  6. Safety Features: Depending on the design and application, disconnect switches may include additional safety features, such as padlockable handles, shrouded terminals, and safety interlocks to prevent unintended operation.

  7. Handle Position Indicators: Some switches have handle position indicators, often color-coded, to clearly show the status of the switch (e.g., green for “ON” and red for “OFF”).

The primary purpose of a three-phase disconnect switch is to provide a means for safely isolating electrical equipment or circuits from the power source. This is essential for maintenance, servicing, emergency shutdowns, and ensuring the safety of personnel working on electrical systems. The manual operation and visible break feature make it easy for operators to verify the status of the switch, and the arc suppression mechanisms help reduce the risks associated with arcing.

It’s important to follow all safety procedures and local electrical codes when operating and maintaining three-phase disconnect switches to ensure safe and compliant operation.

 

How do you wire a 3 phase disconnect switch?

Wiring a three-phase disconnect switch involves connecting the switch to the power source and the load it controls. Proper wiring is essential for safety and reliable operation. Here are the general steps for wiring a three-phase disconnect switch:

Safety Precautions:

  • Ensure that the power source is de-energized and locked/tagged out to prevent accidental energization during the installation.
  • Use appropriate personal protective equipment, such as gloves and safety glasses, when working on electrical systems.

Materials and Tools You Will Need:

  • Three-phase disconnect switch
  • Appropriate electrical conductors (sized according to code)
  • Cable connectors or lugs
  • Wire strippers
  • Screwdrivers
  • Wrenches
  • Torque wrench (for tightening lugs to the specified torque)
  • Safety equipment

Steps for Wiring:

  1. Disconnect Power: Ensure that the power source is turned off and locked/tagged out to prevent electrical hazards.

  2. Select the Location: Mount the disconnect switch in the chosen location, following the guidelines for accessibility, safety clearance, and other factors mentioned in previous responses.

  3. Prepare the Conductors:

    • Prepare the electrical conductors by stripping the insulation from the ends, exposing the bare conductive wire.
    • Install the appropriate cable connectors or lugs on the conductor ends.
  4. Connect the Conductors:

    • Connect the incoming power conductors to the line side of the disconnect switch. Typically, there are terminals labeled L1, L2, and L3 for the three phases.
    • Ensure that the connections are secure and tight, and use a torque wrench to tighten the lug connections to the manufacturer’s specified torque values. Proper torque helps maintain a reliable electrical connection and reduces the risk of overheating.
  5. Connect the Load Conductors:

    • Connect the load-side conductors to the load terminals of the disconnect switch. These may also be labeled L1, L2, and L3. Ensure proper connections and torque values.
  6. Grounding: Connect the equipment grounding conductor to the ground terminal on the disconnect switch as required by electrical codes. Grounding is essential for safety and to provide a path for fault current.

  7. Inspect the Wiring: Carefully inspect all the connections to ensure they are secure and properly tightened. Check for any loose or damaged components.

  8. Seal or Cap Unused Openings: If the disconnect switch has unused openings or knockouts, seal or cap them to prevent dust, moisture, or foreign objects from entering the enclosure.

  9. Test the Switch: After verifying the correct installation, restore power to the disconnect switch if it was previously disconnected. Test the disconnect switch to ensure it operates correctly and that power can be safely disconnected and reconnected.

  10. Labeling: Label the disconnect switch to indicate its purpose and the circuits it controls. Proper labeling is crucial for safety and maintenance.

  11. Documentation: Maintain detailed documentation of the installation, including wiring diagrams and any changes made during the installation.

Always follow local electrical codes and regulations when wiring a three-phase disconnect switch. If you are unsure about any aspect of the installation, it’s advisable to consult with a licensed electrician or a qualified electrical engineer to ensure that the wiring meets safety and code requirements for your specific electrical system.

 

What size 3 phase disconnect switch do I need?

Selecting the right size for a three-phase disconnect switch depends on several factors, including the load it will control and the specific requirements of your electrical system. To determine the appropriate size for your disconnect switch, consider the following steps:

  1. Determine the Load Current: Identify the total current that the disconnect switch will be required to handle. This involves calculating the sum of the current ratings of all the devices or loads that will be connected to the switch. These loads may include motors, pumps, lighting circuits, HVAC systems, or other equipment.

  2. Allow for Future Expansion: Consider any potential future loads that might be added to the circuit. If you anticipate additional equipment being connected to the disconnect switch in the future, it’s wise to choose a disconnect switch with a higher ampacity to accommodate these future loads.

  3. Check Local Electrical Codes: Consult local electrical codes and regulations, which often specify minimum ampacity requirements for disconnect switches in various applications. Ensure that the disconnect switch you select meets these requirements.

  4. Short-Circuit Current Rating (SCCR): Verify that the disconnect switch has a suitable short-circuit current rating (SCCR) that matches or exceeds the available fault current at the installation location. The SCCR ensures the switch can safely interrupt fault currents without causing damage.

  5. Voltage Rating: Ensure that the voltage rating of the disconnect switch matches or exceeds the nominal voltage of your three-phase electrical system (e.g., 208V, 240V, 480V, etc.).

  6. Environmental Conditions: Consider the environmental factors where the disconnect switch will be installed. Outdoor or harsh industrial environments may require disconnect switches with appropriate enclosures and environmental ratings (e.g., NEMA or IP ratings).

  7. Continuous vs. Non-Continuous Loads: Determine whether the connected loads are continuous or non-continuous. Continuous loads are those expected to operate for three hours or more, while non-continuous loads operate for less than three hours. Some codes may require sizing the disconnect switch based on continuous loads.

  8. Safety Margin: It is generally advisable to select a disconnect switch with an ampacity rating that provides a safety margin. Choosing a switch with a slightly higher ampacity than the calculated load current can prevent overloading and ensure safe operation.

  9. Type of Switch: Consider whether you need a non-fused or fused disconnect switch based on your protection requirements. Fused disconnect switches include overcurrent protection via fuses, while non-fused switches do not.

  10. Coordination with Circuit Protection Devices: Ensure that the selected disconnect switch coordinates with circuit protection devices such as circuit breakers or fuses downstream to provide proper overcurrent protection.

Always consult with a qualified electrical engineer or a licensed electrician when determining the correct size for a three-phase disconnect switch. They can perform load calculations and consider all relevant factors to ensure the safe and efficient operation of your electrical system while complying with local electrical codes and regulations.

 

Where should a 3 phase disconnect switch be installed?

The installation location of a three-phase disconnect switch is critical for safety, accessibility, and proper operation. It should be strategically placed to ensure that the switch serves its intended purpose effectively and complies with electrical codes and safety regulations. Here are some guidelines for determining where to install a three-phase disconnect switch:

  1. Accessibility and Visibility:

    • The disconnect switch should be easily accessible to authorized personnel for routine maintenance, servicing, and emergency shutdowns.
    • It should be located in a visible and easily recognizable position to ensure that it can be quickly identified and operated when necessary.
  2. Proximity to Equipment:

    • The disconnect switch should be positioned as close as possible to the equipment or circuits it controls. This minimizes the length of conductors and helps maintain electrical efficiency.
    • In motor control applications, the disconnect switch is often located near the motor.
  3. Clearance Space:

    • Ensure that there is adequate clearance space around the disconnect switch to allow for safe and unobstructed operation.
    • Electrical codes and standards may specify minimum clearance requirements, which must be followed.
  4. Protection from Environmental Factors:

    • Consider the environmental conditions where the switch will be installed. Outdoor or harsh industrial environments may require disconnect switches with suitable enclosures and environmental ratings, such as NEMA or IP ratings.
  5. Avoid Wet or Hazardous Locations:

    • Disconnect switches should not be installed in wet or hazardous locations, unless they are specifically designed and rated for such environments.
    • Avoid locations prone to flooding or exposure to corrosive substances.
  6. Elevation:

    • The switch should be mounted at an appropriate height to prevent unauthorized access and to keep it out of reach of floodwaters or potential damage from equipment or machinery.
  7. Proximity to Control Panels:

    • In industrial settings, disconnect switches are often located near control panels or distribution boards to provide a convenient means for isolating power to these panels.
  8. Labeling and Identification:

    • Install clear and permanent labeling to indicate the purpose of the disconnect switch and the circuits or equipment it controls.
  9. Emergency Shut-off Requirements:

    • In areas where emergency shutdowns may be required, such as near hazardous equipment, chemical processes, or high-risk areas, ensure that the disconnect switch is readily accessible and easily operable.
  10. Electrical Code Compliance:

    • Always follow local electrical codes and regulations when determining the installation location of the disconnect switch.
  11. Safety Considerations:

    • Ensure that the installation location is safe for authorized personnel to operate the switch, with due consideration for personal protective equipment (PPE) and safety protocols.
  12. Maintenance Access:

    • Allow adequate space and access for maintenance personnel to work on the switch, including space for tools and equipment.
  13. Coordination with Lockout/Tagout Procedures:

    • Coordinate the placement of the disconnect switch with lockout/tagout procedures to ensure that it can be safely locked out during maintenance.

The specific installation location of a three-phase disconnect switch will vary based on the application, industry, and facility requirements. It’s important to consult with a qualified electrical engineer or a licensed electrician who is familiar with local codes and regulations to ensure that the installation location complies with safety and code requirements for your specific electrical system.

 

What features should I look for in a 3 phase disconnect switch?

When selecting a three-phase disconnect switch, it’s important to consider several features and characteristics to ensure that the switch meets your specific needs and safety requirements. Here are some key features to look for in a three-phase disconnect switch:

  1. Ampacity Rating: Choose a disconnect switch with an ampacity rating that matches or exceeds the maximum current load of the circuits or equipment it will control. Proper ampacity ensures safe and efficient operation.

  2. Voltage Rating: Ensure that the voltage rating of the disconnect switch matches or exceeds the nominal voltage of your three-phase electrical system (e.g., 208V, 240V, 480V, etc.).

  3. Fused or Non-Fused: Determine whether you need a non-fused or fused disconnect switch based on your overcurrent protection requirements. Fused disconnect switches incorporate fuses to protect against overloads and short circuits, while non-fused switches do not provide overcurrent protection.

  4. Short-Circuit Current Rating (SCCR): Verify that the disconnect switch has a suitable short-circuit current rating that matches or exceeds the available fault current at the installation location. The SCCR ensures the switch can safely interrupt fault currents.

  5. Enclosure Type: Consider the environmental conditions where the switch will be installed. Choose an enclosure type that provides protection against dust, moisture, corrosive substances, and other environmental factors. Enclosure ratings, such as NEMA or IP ratings, should match the installation environment.

  6. Handle Type: Select a disconnect switch with an appropriate handle type, such as a rotary handle, pistol grip, or knife blade. The handle design should be ergonomic and suitable for the intended application.

  7. Visible Break: Look for a disconnect switch that provides a visible break when in the “OFF” position. A visible break ensures that the circuit is safely disconnected and easily identifiable.

  8. Lockout/Tagout Provisions: Ensure that the disconnect switch has provisions for lockout/tagout, which allows authorized personnel to secure the switch in the “OFF” position during maintenance or servicing.

  9. Grounding Provisions: Look for switches with proper grounding provisions, such as ground terminals, to ensure a reliable ground connection for safety.

  10. Safety Features: Consider additional safety features, such as shrouded terminals, padlockable handles, and safety interlocks, if needed for your application.

  11. Coordination with Circuit Protection: Ensure that the disconnect switch coordinates effectively with circuit protection devices, such as circuit breakers or fuses, to provide proper overcurrent protection.

  12. Mounting Type: Determine whether the switch will be surface-mounted, flush-mounted, or pole-mounted, based on the installation requirements and constraints of your facility.

  13. Elevation: Consider the appropriate elevation or height at which the disconnect switch should be installed to prevent unauthorized access and protect it from environmental factors.

  14. Labeling and Identification: Choose a switch with clear and permanent labeling to indicate its purpose and the circuits or equipment it controls.

  15. Emergency Shut-off Requirements: If the switch will be used for emergency shut-offs, ensure it is designed to be easily accessible and operable in emergency situations.

  16. Durability and Reliability: Look for high-quality construction and materials to ensure the switch’s long-term durability and reliable performance.

  17. Local Electrical Code Compliance: Always follow local electrical codes and regulations when selecting a disconnect switch to ensure it meets the safety and code requirements for your specific application.

The specific features you prioritize will depend on the nature of your application, industry, and facility requirements. Consulting with a qualified electrical engineer or a licensed electrician is advisable to select the appropriate three-phase disconnect switch for your specific needs while ensuring safety and code compliance.

 

GRL‘s Honor Products

60mm busbar system

Busbar System

60mm/100mm/185mm/terminal distribution Busbar System

GRL Fuse type disconnect switch

Disconnect switch

Fuse type disconnect switch

GRL-Knife switch

Knife switch

Different kinds of Knife switch

GRL Fuses and Fuseholders

Fuse & Fuse holders

Fuse & Fuse holders

You'll receive a response ASAP!